Highlights of HumiSeal UV20GEL

Product Specification

Uncured Properties

Property

Value

Solvent Content

No Nonreactive Solvents

Chemical Class

Acrylated Urethane

Appearance

Opaque White

Density, g/mL

1.08

Viscosity

Non-sag Thixotropic Paste

Thixotropic Index

> 5.5

Cured Properties

Property

Value

Hardness, Shore A (Initial)

10

Hardness, Shore A (10 days post cure)

60

Tensile Strength, MPa [psi]

4.8 [700]

Elongation, %

>400

Moisture Resistance

Excellent

Surface Resistivity, Ohm

1.4*1012

Volume Resistivity, Ohm*cm

8.5*1013

Dielectric Withstand Voltage (per MIL-I-46058C)

Pass @ 1500 V

Peak Operating Temperature, °C

-40 to 125

Polycarbonate Lap Shear, psi

 200

PVC Lap Shear, psi

450

Application of UV20GEL Staking Material

 

Curing

HumiSeal® UV20GEL is a highly cross-linked material.  In order to achieve maximum cross-link density and physical performance, the product must be exposed to the correct spectral output.

HumiSeal®UV20GEL can be cured using arc, microwave, or LED systems.  Exact dosage is application dependent, however recommended dosage is 4 J/cm2 for arc and microwave systems and 10 J/cm2 for LED lamps.  Because of the variations possible in curing equipment type and configuration, it is strongly recommended that you contact HumiSeal Technical Support to discuss your equipment and process in detail.

HumiSeal® UV20GEL contains a reliable secondary moisture cure mechanism which will cure any shadow areas on the assembly within 7-10 days at ambient moisture.

Storage

HumiSeal® UV20GEL should be stored in a cool, dry, and dark location at a temperature between 1°C to 25°C. Material is sensitive to moisture, UV, and visible light. Consult SDS for safe handling recommendations.  Consult packaging labels for recommended shelf life. 

Caution

Application of HumiSeal® UV20GEL should be carried out in accordance with local and National Health and Safety regulations. Use only in well-ventilated areas to avoid inhalation of vapors.  Avoid contact with skin and eyes. Consult SDS prior to use.

See more
Hide
Have 0 comment

Welcome. Feel free to leave a comment, we will respond soon

Reply.
Thông tin người gửi
Click here to rate
Thông tin người gửi
0.15801 sec| 2679.602 kb