HumiSeal UV40HV
4 5 (1 evaluate)Category: UV Curabel
Manufacturer: Humiseal
Packaging: 5L, 20L
Origin: UK or USA
Product Specification
Density |
1.05 – 1.15 g/cm3 |
Minimum Solids Content |
95 % |
Viscosity, per Fed-Std-141, Meth. 4287 |
3700 ± 1300 centipoise |
Recommended UV Cure* |
See TDS for Details |
Shelf Life at Room Temperature, DOM |
12 months |
Recommended Stripper ** |
HumiSeal® Stripper 1100 |
Thermal Shock, 50 cycles per MIL-I-46058C |
-65°C to 125°C |
Glass Transition Temperature – DSC |
45°C |
Coefficient of Thermal Expansion – TMA |
85 ppm/°C Below Tg |
Dielectric Withstand Voltage, per MIL-I-46058C |
>1500 volts |
Dielectric Constant, at 1MHz and 25°C per ASTM D150-98 |
2.5 |
Dissipation Factor, at 1MHz and 25°C per ASTM D150-98 |
0.01 |
Insulation Resistance, per MIL-I-46058C |
8.0 x 1014 ohms (800TΩ) |
Moisture Insulation Resistance, per MIL-I-46058C |
4.7 x 1010 ohms (47GΩ) |
Fungus Resistance, per ASTM G21 |
Pass |
HumiSeal UV40HV offers the following features:
-
single component
-
high solids/high viscosity
-
UV curable
-
acrylated polyurethane
-
excellent chemical resistance, surface hardness, flexibility, and moisture resistance.
-
secondary moisture cure mechanism for curing in the non-UV exposed shadowed areas
-
fluoresces under UV light to allow for coating inspection
-
can be applied by selective coating equipment.
-
IPC-CC-830 and RoHS directive 2015/863/EU
-
China Standard GB30981-2020
Application of UV40HV
To ensure proper application, conformal coatings should be applied to substrates that have been cleaned prior to coating, as well as to those assembled with low-residue, “no clean” materials. It is essential for users to perform adequate testing to confirm compatibility between the conformal coating and their specific assembly materials, process conditions, and cleanliness levels. For further assistance, please contact HumiSeal®.
Spraying
HumiSeal® UV40HV can be applied using standard selective coating equipment or conventional hand spray equipment. To prevent premature curing of the secondary cure mechanism, dry source air (inert gases such as nitrogen or argon are recommended) should be used. Proper ventilation is necessary to carry away any vapor and mist from the operator.
Brushing
For rework or touch-ups, HumiSeal® UV40HV may be applied by brush. Brushes should be cleaned promptly with solvent after use.
Clean Up
Non-alcohol-based solvents should be used to flush equipment and clean uncured HumiSeal® UV40HV. HumiSeal® Thinner 521 or Thinner 521EU is recommended for this purpose.
Rework
HumiSeal® UV40HV forms a highly cross-linked, UV-cured coating that offers excellent environmental and chemical resistance. As a result, it may be more difficult to remove than traditional conformal coatings. Thermal displacement, mechanical abrasion, or HumiSeal® Stripper 1100 can be used to facilitate rework of the cured coating.