HumiSeal UV40 SOLAR
4 5 (1 evaluate)Category: UV Curabel
Manufacturer: Humiseal
Packaging: 5L, 20L
Origin: UK or USA
Product Specification
Density |
1.06 g/cm3 |
Minimum Solids Content |
95 % |
Viscosity, per Fed-Std-141, Meth. 4287 |
650 ± 150 centipoise |
Recommended Coating Thickness |
25-125 microns |
Recommended UV Cure* |
See TDS for Details |
Shelf Life at Room Temperature, DOM |
12 months |
Thermal Shock, 50 cycles per MIL-I-46058C |
-65ºC to 125ºC |
Glass Transition Temperature – DSC |
45ºC |
Coefficient of Thermal Expansion – TMA |
85 ppm/ºC Below Tg |
Modulus – DMA |
10364 MPa @ -40°C |
Dielectric Withstand Voltage, per MIL-I-46058C |
>1500 votls |
Dielectric Constant, at 1MHz and 25°C per ASTM D150-98 |
2.5 |
Dissipation Factor, at 1MHz and 25°C per ASTM D150-98 |
0.01 |
Insulation Resistance, per MIL-I-46058C |
8.0 x 1014 ohms (800TΩ) |
Moisture Insulation Resistance, per MIL-I-46058C |
4.7 x 1010 ohms (47GΩ) |
Fungus Resistance, per ASTM G21 |
Pass |
HumiSeal UV40 SOLAR offers the following features:
-
single component
-
high solids
-
UV curable
-
acrylated polyurethane
-
no-yellowing with exposure to UV
-
meets requirements of SAA-J1960
-
excellent chemical resistance, surface hardness, flexibility and moisture resistance.
-
secondary moisture cure mechanism for curing in the non-UV exposed shadowed areas
-
can be applied by selective coating equipment.
-
recognized under UL File Number E105698
-
MIL-I-46058C qualified
-
IPC-CC-830 and RoHS directive 2015/863/EU
Application of HumiSeal UV40 SOLAR
HumiSeal® UV40 SOLAR is designed to be applied to substrates that are either cleaned prior to coating or assembled using low residue, “no clean” materials. It is essential for users to conduct appropriate testing to ensure compatibility between the conformal coating and their assembly materials, process conditions, and cleanliness levels. For further information, please contact HumiSeal®.
Spraying
HumiSeal® UV40 SOLAR can be applied using standard selective coating equipment or conventional hand spray methods. It is crucial to use dry source air (inert gases like nitrogen are highly recommended) to avoid premature curing of the secondary cure mechanism. Ensure proper ventilation to dissipate vapor and mist from the operator's area.
Brushing
HumiSeal® UV40 SOLAR may be applied by brush for rework or touch-up purposes only. Brushes must be cleaned promptly with solvent after use.
Clean Up
To clean uncured HumiSeal® UV40 SOLAR and flush equipment, non-alcohol-based solvents should be utilized. HumiSeal® Thinner 521 or Thinner 521EU is recommended.
Rework
As a highly cross-linked UV-cured coating, HumiSeal® UV40 SOLAR has superior environmental and chemical resistance, making removal more difficult than traditional conformal coatings. Rework can be performed using thermal displacement, mechanical abrasion, or, where available, HumiSeal® Stripper 1100.