HumiSeal 1C49
4 5 (1 evaluate)Category: Silicones
Manufacturer: Humiseal
Packaging: 5L, 20L
Origin: UK or USA
Product Specification
Density, per ASTM D1475 |
0.97 ± 0.03 g/cm³ |
Min. Solids Content, % by weight per Fed-Std-141, Meth. 4044 |
95 % |
Viscosity, per Fed-Std-141, Meth. 4287 |
9000 ± 1500 centipoise |
VOC |
0 grams/litre |
Recommended Coating Thickness |
50 – 200 microns |
Drying Time to Handle per Fed-Std-141, Meth. 4061 |
<10 mins |
Recommended Curing Conditions |
24 hrs @ RT or 20 min @ 76°C* |
Time required to Reach Optimum Properties |
7 days |
Recommended Stripper |
HumiSeal Stripper 1091 |
Shelf Life at Room Temperature, DOM |
12 months |
Thermal Shock, 50 cycles per MIL-I-46058C |
-65°C to 200°C |
Coefficient of Thermal Expansion – TMA |
367 ppm /ºC |
Glass Transition Temperature – DSC |
< -65°C |
Storage Modulus – DMA |
408 MPa @ -40ºC |
Tensile, per ASTM D412 |
30-50 psi |
Elongation, per ASTM D412 |
80-120 % |
Build per Dip, per ASTM D823 |
5 mils |
Flammability, per UL94 |
V-1 |
Dielectric Withstand Voltage, per MIL-I-46058C |
>1500 volts |
Dielectric Breakdown Voltage, per ASTM D149 |
7000 volts |
Dielectric Constant, at 1MHz and 25°C per ASTM D150-98 |
2.5 |
Dissipation Factor, at 1MHz and 25°C per ASTM D150-98 |
0.01 |
Insulation Resistance, per MIL-I-46058C |
5.0 x 1014 ohms (500TΩ) |
Moisture Insulation Resistance, per MIL-I-46058C |
1.0 x 1010 ohms (10GΩ) |
Fungus Resistance, per ASTM G21 |
Passes |
HumiSeal 1C49 offers the following features:
-
silicone based
-
fluoresces under UV light
-
room temperature, moisture cure
-
single component
-
high solids
-
no VOCs or solvent
-
low toxicity
-
excellent environmental resistance and moisture resistance
-
RoHS directive 2015/863/EU
-
Mil-I-46058C qualified
-
IPC-CC-830 qualified
-
recognized under UL file number E105698
Application of HumiSeal 1C49
HumiSeal® 1C49 is designed for easy application without the need for additional thinning. It should not be mixed with solvents or other thinners. This conformal coating can be applied using various methods, including spraying, brushing, flow coating, or dipping. The time to reach a tack-free state depends on ambient conditions such as temperature and relative humidity, with processing guidelines based on a 50% relative humidity environment.
Dipping
To ensure an even coating, use a controlled immersion and withdrawal rate (5-15 cm/min). Blanketing the dip tank with an inert gas like nitrogen can help extend the pot life.
Spraying
HumiSeal® 1C49 can be applied using conventional spraying equipment in a well-ventilated area to ensure vapors and mist are carried away from the operator. Thinner is not required and should not be used with this product.
Brushing
The uniformity of the film will depend on the component density and the technique used by the operator.
AAdministratorsQTV