HumiSeal 1R32A-2/521 PB65
4 5 (1 evaluate)Category: Acrylic Conformal Coating
Manufacturer: Humiseal
Packaging: 5L, 20L
Origin: UK or USA
Product Specification
Density, per ASTM D1475 | 0.91 ± 0.02 g/cm³ |
Solids Content, % by weight per Fed-Std-141, Meth. 4044 | 26 ± 2 % |
Viscosity, per Fed-Std-141, Meth. 4287 | 65 ± 5 centipoise |
VOC | 670 grams/litre |
Drying Time to Handle per Fed-Std-141, Meth. 4061 | 10 minutes |
Recommended Coating Thickness | 25 – 75 microns |
Recommended Curing Conditions | 24 hrs @ RT or 30 min @ 76°C |
Time Required to Reach Optimum Properties | 7 days |
Recommended Stripper | HumiSeal® Stripper 1080 |
Shelf Life at Room Temperature, DOM | 24 months |
Thermal Shock, 50 cycles per MIL-I-46058C | -65°C to 125°C |
Coefficient of Thermal Expansion - TMA | 55 ppm/°C |
Glass Transition Temperature - DSC | 14°C |
Modulus – DMA |
2000 MPa @ -40°C 1050 MPa @ 20°C 8.5 MPa @ 60°C |
Dielectric Withstand Voltage, per MIL-I-46058C | >>1500 volts |
Dielectric Breakdown Voltage, per ASTM D149 | 7500 volts |
Dielectric Constant, at 1MHz and 25°C per ASTM D150-98 | 2.5 |
Dissipation Factor, at 1MHz and 25°C per ASTM D150-98 | 0.01 |
Insulation Resistance, per MIL-I-46058C | 8.0 x 1014 ohm (800TΩ) |
Moisture Insulation Resistance, per MIL-I-46058C | 6.0 x 1010 ohm (60GΩ) |
Fungus Resistance, per ASTM G21 | Passes |
Application of HumiSeal® 1R32A-2/521 PB65
For successful application of HumiSeal® 1R32A-2/521 PB65, the cleanliness of the substrate is critical. Surfaces must be free moisture, dirt, wax, grease, flux residues, and all other contaminants, as contamination under the coating may lead to assembly failures.
Spraying
HumiSeal® 1R32A-2/521 PB65 can be applied using automated spraying equipment. The spraying process should be conducted in a well-ventilated environment to ensure that vapors and mist are effectively carried away the operator.
Storage
HumiSeal® 1R32A-2/521 PB65 should be stored in tightly closed containers, away extreme temperatures. It can be stored between 0°C and 35°C. Before use, allow the product to equilibrate at room temperature (18–32°C) for 24 hours.
Caution
Application of HumiSeal® Conformal Coatings should follow local and national health and safety regulations. As the solvents in HumiSeal® Conformal Coatings are flammable, the material should not be used near open flames or sparks. Ensure use in well-ventilated areas to avoid inhaling vapors or spray. Avoid direct contact with skin and eyes. Always consult the MSDS/SDS prior to use for further safety guidelines.
AAdministratorsQTV
Welcome. Feel free to leave a comment, we will respond soon