HumiSeal 1B73

4 5 (1 evaluate)

Category: Acrylic Conformal Coating

Manufacturer: Humiseal
Packaging: 5L, 20L
Origin: UK or USA

Product code : HumiSeal 1B73
Mua ngay
Liên hệ mua hàng
0877330486
Highlights of HumiSeal 1B73

Product Specification

Density, per ASTM D1475 0.92 ± 0.02 g/cm³
Solids Content, % by weight per Fed-Std-141, Meth. 4044 29.5 ± 2 %
Viscosity, per Fed-Std-141, Meth. 4287 250 ± 20 centipoise
VOC 661 grams/liter
Drying Time to Handle per Fed-Std-141, Meth. 4061 30 minutes
Recommended Coating Thickness 25 -75 microns
Recommended Curing Conditions 24 hrs @ RT or 2 hrs @ 76°C
Time Required to Reach Optimum Properties 7 days
Recommended Thinner HumiSeal® Thinner 73
Recommended Stripper HumiSeal® Stripper 1080, 1080A
Shelf Life at Room Temperature, DOM 24 months
Thermal Shock, 50 cycles per MIL-I-46058C -65°C to 125°C
Coefficient of Thermal Expansion – TMA 67 ppm/°C
Glass Transition Temperature – DSC 42°C
Modulus – DMA 11.1 MPa
Flammability, per UL 94 V-0
Dielectric Withstand Voltage, per MIL-I-46058C >1500 volts
Dielectric Breakdown Voltage, per ASTM D149 6300 volts
Dielectric Constant, at 1MHz and 25°C, per ASTM D150-98  2.6
Dissipation Factor, at 1MHz and 25°C, per ASTM D150-98 0.010
Insulation Resistance, per MIL-I-46058C 5.5 x 1014 ohms (550TΩ)
Moisture Insulation Resistance, per MIL-I-46058C 7.0 x 1010 ohms (70GΩ)
Fungus Resistance, per ASTM G21 Passes

HumiSeal® 1B73 is a single-component, fast-drying acrylic conformal coating that offers excellent flexibility and electrical properties. It fluoresces under UV light for easy inspection and can be easily repaired. HumiSeal® 1B73 is qualified to MIL-I-46058C, meets IPC-CC-830 standards, complies with RoHS Directive 2011/65/EU, and is recognized under UL File Number E105698.

Application of HumiSeal® 1B73

For effective application of conformal coatings, it is essential that substrates are properly cleaned or assembled with low-residue “no clean” materials. Adequate testing should be conducted to ensure compatibility between the conformal coating and specific assembly materials, process conditions, and cleanliness levels. For more information, please reach out to HumiSeal®.

Dipping

To achieve a uniform film on assemblies with varying component configurations and densities, it may be necessary to reduce the viscosity of HumiSeal® 1B73 using HumiSeal® Thinner 73. Once the optimum viscosity is established, a controlled immersion and withdrawal rate of 5-15 cm/min should be maintained to ensure even coating deposition. As the solvent evaporates during application, viscosity increases and should be adjusted by adding small amounts of HumiSeal® Thinner 73.

Spraying

HumiSeal® 1B73 can be sprayed using conventional equipment. Adequate ventilation is required to carry away vapors and mist the operator. To achieve a uniform spray pattern and a pinhole-free film, HumiSeal® Thinner 73 should be added. The recommended ratio of HumiSeal® 1B73 to Thinner 73 is 1:1 by volume, although this may need to be adjusted based on the spray equipment used and operator technique.

Brushing

HumiSeal® 1B73 can also be brushed, with a small addition of HumiSeal® Thinner 73. The uniformity of the coating will depend on the component density and the skill of the operator.

Storage

HumiSeal® 1B73 should be stored in tightly closed containers, away excessive heat or cold, within the temperature range of 0 to 35°C. Allow the product to equilibrate for 24 hours at a room temperature of 18 to 32°C prior to use.

Caution

Ensure that the application of HumiSeal® Conformal Coatings follows local and national health and safety regulations. The solvents used are flammable, and the material should not be used near open flames or sparks. Always work in well-ventilated areas to avoid inhalation of vapors or spray. Avoid skin and eye contact. Please consult the SDS prior to use.